Pole-Mounted Transformers

Working, failed or storm-damaged units come out of plants, pads and vaults anywhere in North Carolina.

What we buy

Ranges we buy on this page

Transformer Buyers NC buys used, surplus, failed and obsolete pole-mounted transformers anywhere in North Carolina. This page covers the single-phase or small three-phase can hung from a pole or a platform, including units already lowered into a utility yard.

For utility asset managers, farm owners, facility directors and demolition crews, the practical issues are identification, oil records, tank condition and safe removal. A corroded pole bracket can complicate an otherwise straightforward recovery.

PhasekVAVoltageFluid
1-phase10 - 167 kVA25 kVLiquid-filled

Who we buy from

Six kinds of seller

  • Recyclers
  • Electrical contractors
  • Equipment dealers
  • End users
  • Demo contractors
  • Distributors
Yard row of pad-mounted transformers of several vintages seen from the gate
The yard row from the gate, pad-mounts at different vintages. Yard view: our library holds no frame of this class, so the page shows the yard these units leave from.
  • Fast offers

    A written offer the same business day, based on your photographs.

  • Dedicated logistics

    Our own crew, trailer and crane, not a brokered haul.

  • No broker fees

    One buyer from first call to cleared pad, with nothing skimmed.

How it works

Six steps from photograph to payment

  1. 01

    Take pictures

    Photograph the nameplate, the inside of the cabinet and the tank from both ends. Four frames on a phone are enough to price most units.

  2. 02

    Send them to us

    Email or text the photographs with the site address and whether the unit is still energised. We reply the same business day with questions or a number.

  3. 03

    Review the offer

    The offer names the unit, the site, the price and the pickup window. It is written, dated and good for thirty days unless the unit changes hands.

  4. 04

    We schedule freight

    A crew, a trailer and a crane if the pad needs one. You get the date and the arrival window, and the site does not have to close for it.

  5. 05

    Testing on arrival

    Winding resistance, insulation resistance and a turns ratio check, plus oil analysis where the unit is liquid-filled. Results travel with the unit.

  6. 06

    Get paid

    Payment is released against the signed bill of sale and the scale ticket, by check or ACH, with the paperwork copy left on site.

What we handle

The parts sellers dread

  • Rigging

    Crane, skates and a route survey for anything that will not roll onto a trailer.

  • Oil containment

    Pans, absorbent and a spill plan before a drain plug is touched.

  • Bill of sale

    A document that clears a lien, a lease or a bankruptcy file, not a handwritten note.

  • PCB paperwork

    Testing and manifesting for pre-1979 oil, handled before the unit moves.

On the ground

The unit itself

A pole-mounted transformer usually has a cylindrical steel tank, lifting lugs and brackets that attach to pole hardware. Single-phase cans commonly serve individual loads; three single-phase units may form a three-phase bank.

A small three-phase unit can also sit on a platform, so the mounting arrangement alone does not establish its electrical configuration.

The nameplate separates a familiar-looking can from an identifiable unit. Record the manufacturer, serial number, kVA, primary voltage, secondary voltage and impedance where legible.

A 7,200-volt primary and 120/240-volt secondary are useful identifying details, but never infer those ratings from the number of bushings or the tank diameter alone.

Local reality

Where you find pole-mounted in this state

Across North Carolina, pole-mounted cans appear on rural co-op lines, at farms, beside small shops and along older residential distribution circuits.

A farm service may have one can above a meter pole, while a shop motor load may use a bank of three cans with separate secondary connections below.

Ownership matters before any removal discussion. The can above a private driveway may belong to the serving utility even when the pole stands on private land.

At an older mill or farm complex, check utility agreements, asset tags and service drawings rather than treating every transformer inside the fence as owner-controlled equipment.

Around the site

Our inspection list

We inspect tank rust, especially around the bottom seam, hanger brackets and lifting lugs. Surface oxidation differs from deep pitting or a seam that has started to weep.

Photographs should show the full tank, underside where safely visible, mounting hardware and any rust trails running below the cover or bushings.

The cover gasket, oil level and evidence that the unit is PCB-free are separate checks. Look for oil staining around the lid and cracked porcelain at the bushings without opening the tank.

A faded PCB label is not a substitute for a legible manufacturer statement or an applicable oil test report.

Where it sits

Testing, oil and liability

Useful records include the removal date, reason for retirement, maintenance history and any winding resistance, insulation resistance or turns-ratio results. A can removed after a lightning event needs different scrutiny from one retired during a line rebuild.

Record whether a fuse operated, a bushing flashed over or the tank leaked.

Oil sampling belongs with qualified personnel using suitable procedures and documented sample identification. Match any PCB analysis to the serial number or another traceable asset identifier.

If oil status is unknown, leave it identified as unknown; do not drain a pole can into an unmarked drum or mix its oil with other units.

On the ground

Load-out and haul

A pole can is lowered by a bucket truck or a line crew with rated lifting equipment, after the serving circuit has been isolated and made safe by authorized personnel. The bucket is not automatically a lifting device.

Verify approved lifting points and keep slings clear of porcelain bushings and secondary terminals.

The pole itself is often the bigger problem: decay at the ground line, a leaning top or crowded conductors can limit access. Once lowered, keep the can upright on a stable base, secure it against movement and protect protruding bushings.

Confirm truck access around farm gates, soft shoulders and overhead service drops.

Local reality

Valuation factors

The assessment starts with the pole can's identity and condition: kVA, voltage combination, age, manufacturer and completeness. Intact bushings, readable markings and sound hanger brackets help establish what is present.

A stripped tank with missing leads or a failed winding needs to be described differently from a complete retired unit.

Oil documentation and removal conditions also shape the review. Separate PCB-free records from assumptions based on appearance, and identify whether the can remains energized, hangs on a damaged pole or sits upright in a yard.

For a three-can bank, provide each nameplate rather than one rating assigned to the entire group.

Around the site

How to start the conversation

Begin with the North Carolina location, ownership confirmation and whether the transformer is still on the pole. Send clear photographs of the nameplate, tank, bushings and hanger brackets taken from a safe position.

Include the number of cans and explain whether they are individual units or parts of a three-phase bank.

Add the known failure history, oil or PCB records and the contact responsible for utility coordination. For a farm or demolition site, describe gate width, ground conditions and who will lower the can.

That information establishes the removal boundary before anyone schedules equipment around a pole that may still carry live conductors.

Get started

Get an offer in minutes

Five fields is all it takes. Photographs help, but a nameplate and a town are enough to start.

No fee, no obligation. We reply the same business day.

Tell us what you have

We reply the same business day.

or call (614) 715-3047

Questions

Straight answers

Equipment types

Can you buy a transformer still on its pole?

We can review a pole-mounted unit before removal, but ownership and electrical status must be established first. Provide the nameplate information and identify the utility or authorized line crew responsible for isolation and lowering. Do not approach energized bushings to obtain photographs.

Service area

What if the pole can has no PCB label?

A missing label leaves PCB status unresolved; it does not prove the oil contains PCBs or is PCB-free. Provide manufacturer records or a traceable oil analysis if available. Keep the tank closed and report any leak while the documentation is reviewed.

Payment

Should I list three banked cans separately?

Yes. Record each can's serial number, kVA, voltage ratings and condition. A three-phase bank can contain units with different histories, and one failed can does not establish the condition of the other two. Include a photograph showing the bank arrangement if safely obtainable.

Logistics

Testing, oil and liability: what should a seller know?

Useful records include the removal date, reason for retirement, maintenance history and any winding resistance, insulation resistance or turns-ratio results. A can removed after a lightning event needs different scrutiny from one retired during a line rebuild.

One buyer, start to finish

Ready to move that transformer?