What we buy
Ranges we buy on this page
This page covers selling used, surplus, failed and obsolete 37.5 kVA transformers in North Carolina. It is for plant engineers, utility asset managers, facility directors, contractors and demolition crews handling a single-phase padmount at a small commercial building or church.
Transformer Buyers NC buys these units statewide. The details below explain nameplate records, roughly 300 to 450 pounds of shipping weight, voltage identification, oil inspection and safe load-out planning.
| Phase | kVA | Voltage | Fluid |
|---|---|---|---|
| 1 or 3-phase | 37.5 kVA | up to 34.5 kV | Liquid or dry |
| 3-phase | 50 - 20,000 kVA | 46 kV | Liquid or dry |
Who we buy from
Six kinds of seller
- Recyclers
- Electrical contractors
- Equipment dealers
- End users
- Demo contractors
- Distributors

Fast offers
A written offer the same business day, based on your photographs.
Dedicated logistics
Our own crew, trailer and crane, not a brokered haul.
No broker fees
One buyer from first call to cleared pad, with nothing skimmed.
How it works
Six steps from photograph to payment
- 01
Take pictures
Photograph the nameplate, the inside of the cabinet and the tank from both ends. Four frames on a phone are enough to price most units.
- 02
Send them to us
Email or text the photographs with the site address and whether the unit is still energised. We reply the same business day with questions or a number.
- 03
Review the offer
The offer names the unit, the site, the price and the pickup window. It is written, dated and good for thirty days unless the unit changes hands.
- 04
We schedule freight
A crew, a trailer and a crane if the pad needs one. You get the date and the arrival window, and the site does not have to close for it.
- 05
Testing on arrival
Winding resistance, insulation resistance and a turns ratio check, plus oil analysis where the unit is liquid-filled. Results travel with the unit.
- 06
Get paid
Payment is released against the signed bill of sale and the scale ticket, by check or ACH, with the paperwork copy left on site.
What we handle
The parts sellers dread
Rigging
Crane, skates and a route survey for anything that will not roll onto a trailer.
Oil containment
Pans, absorbent and a spill plan before a drain plug is touched.
Bill of sale
A document that clears a lien, a lease or a bankruptcy file, not a handwritten note.
PCB paperwork
Testing and manifesting for pre-1979 oil, handled before the unit moves.
On the ground
The 37.5 kVA class
A 37.5 kVA nameplate identifies apparent power capacity, not the building's measured demand. On a single-phase padmount, the rating belongs with the primary voltage, secondary voltage and cooling designation.
Photograph the entire plate before weathering or removal makes small stamped characters unreadable.
For a church service replacement in North Carolina, confirm that the retired tank actually carries a 37.5 kVA rating. Cabinet size alone cannot establish capacity. Record the manufacturer, serial number and manufacture date so the equipment description follows the unit through removal.
Local reality
Typical North Carolina applications
A single-phase 37.5 kVA padmount can serve a small commercial building or a church with modest electrical demand.
In North Carolina, establish whether the unit belongs to the property owner or serving utility before arranging removal; location on private property does not establish ownership.
At a church renovation or small commercial demolition, compare the 37.5 kVA nameplate with the electrical drawings and service records. A contractor should distinguish the retired transformer from equipment still feeding lighting, refrigeration or other occupied spaces before the disconnect work begins.
Around the site
Shipping weight and footprint
Shipping weight for the 37.5 kVA equipment described here is roughly 300 to 450 pounds. Verify the actual unit's weight before selecting lifting equipment. Oil volume, tank construction and cabinet arrangement affect the load; a visual estimate is not a rigging specification.
Measure the 37.5 kVA padmount cabinet's width, depth and height, including projecting hinges or handles. Record the concrete pad dimensions separately.
Photographs should show the cabinet base and surrounding clearance so the crew can plan access without mistaking pad size for equipment footprint.
Where it sits
Rigging and load-out
Plan a small crane or a boom truck for the roughly 300 to 450 pound unit. A half-ton pickup will not do for this load-out.
Truck payload alone does not provide controlled lifting, suitable tie-down points or a safe way off the pad.
Before lifting a 37.5 kVA padmount, qualified personnel must isolate the circuit, verify absence of voltage and complete required grounding. Inspect lifting provisions and confirm the manufacturer's instructions. Never rig from a bushing, elbow, cabinet handle or radiator, if one is fitted.
On the ground
Primary and secondary voltages
A 37.5 kVA rating does not identify primary voltage. Read the nameplate rather than assuming the local feeder voltage applies.
Include tap information and whether the primary connection is phase-to-neutral; these details help distinguish units that look alike from outside the cabinet.
For a single-phase unit marked 120/240 volts secondary, rated current is approximately 156 amperes at 240 volts. That calculation does not establish service conductor size or protection requirements.
Photograph secondary terminals and connection markings without entering an energized 37.5 kVA transformer's compartment.
Local reality
Inspection and oil test
Inspect a de-energized 37.5 kVA tank for gasket seepage, corrosion near the base, damaged bushings and evidence of overheating. Photograph each defect before cleaning.
A wet patch beneath the cabinet needs investigation; it should not automatically be described as rainwater or harmless residue.
For an oil-filled 37.5 kVA unit, provide existing dielectric breakdown, moisture and PCB laboratory reports when available. Match each report to the serial number and sample date.
Qualified personnel should collect any new sample using the appropriate procedure, without opening an energized compartment.
Around the site
Valuation for this size
Assessment of a retired 37.5 kVA transformer starts with the nameplate, ownership documentation and condition photographs. A complete, sealed tank with readable records presents a different handling case from a failed unit with missing bushings, leaked oil or an unreadable serial number.
For this roughly 300 to 450 pound class, removal conditions also matter: crane access, pad clearance, disconnection status and oil containment requirements. Transformer Buyers NC buys used, surplus, failed and obsolete units across North Carolina, with each transformer reviewed against its documented condition.
Get started
Get an offer in minutes
Five fields is all it takes. Photographs help, but a nameplate and a town are enough to start.
No fee, no obligation. We reply the same business day.
Tell us what you have
We reply the same business day.
Questions
Straight answers
Equipment types
Can you buy a failed 37.5 kVA transformer?
Yes. Transformer Buyers NC buys failed 37.5 kVA units in North Carolina. Describe the failure, identify any oil leak and provide nameplate photographs. Keep inspection reports and utility release paperwork with the equipment record, particularly after a fault or fire.
Service area
What truck should handle a 37.5 kVA padmount?
Plan a small crane or boom truck for lifting and load-out. The roughly 300 to 450 pound shipping weight must be verified for the actual unit. A half-ton pickup will not do; the plan needs controlled lifting and proper securement.
Payment
Who can authorize removal from a church property?
The documented equipment owner must authorize removal of the 37.5 kVA transformer. A church-owned building may have a utility-owned padmount outside. Confirm ownership through service records and the serving utility, then have qualified personnel complete isolation before lifting begins.
Logistics
Primary and secondary voltages: what should a seller know?
A 37.5 kVA rating does not identify primary voltage. Read the nameplate rather than assuming the local feeder voltage applies.