Transformer Buyers NC Sell a unit(614) 715-3047
Pad-mounted transformer in the yard with further units behind it

Crew and crane included

75 kVA Transformers Transformers

A unit at this rating is worth a photograph: nameplate, cabinet interior and both ends of the tank.

What we buy

Ranges we buy on this page

Transformer Buyers NC buys used, surplus, failed and obsolete 75 kVA transformers anywhere in North Carolina.

For a machine shop shutdown or retail building demolition, useful starting information includes the nameplate, voltage connections, oil condition, shipping weight and access around the concrete pad.

PhasekVAVoltageFluid
1 or 3-phase75 kVAup to 34.5 kVLiquid or dry
3-phase50 - 20,000 kVA46 kVLiquid or dry

Who we buy from

Six kinds of seller

  • Recyclers
  • Electrical contractors
  • Equipment dealers
  • End users
  • Demo contractors
  • Distributors
Finned pad-mounted transformer on a concrete pad in front of a brick plant wall
A finned pad-mount on a pad, brick plant wall behind.
  • Fast offers

    A written offer the same business day, based on your photographs.

  • Dedicated logistics

    Our own crew, trailer and crane, not a brokered haul.

  • No broker fees

    One buyer from first call to cleared pad, with nothing skimmed.

How it works

Six steps from photograph to payment

  1. 01

    Take pictures

    Photograph the nameplate, the inside of the cabinet and the tank from both ends. Four frames on a phone are enough to price most units.

  2. 02

    Send them to us

    Email or text the photographs with the site address and whether the unit is still energised. We reply the same business day with questions or a number.

  3. 03

    Review the offer

    The offer names the unit, the site, the price and the pickup window. It is written, dated and good for thirty days unless the unit changes hands.

  4. 04

    We schedule freight

    A crew, a trailer and a crane if the pad needs one. You get the date and the arrival window, and the site does not have to close for it.

  5. 05

    Testing on arrival

    Winding resistance, insulation resistance and a turns ratio check, plus oil analysis where the unit is liquid-filled. Results travel with the unit.

  6. 06

    Get paid

    Payment is released against the signed bill of sale and the scale ticket, by check or ACH, with the paperwork copy left on site.

What we handle

The parts sellers dread

  • Rigging

    Crane, skates and a route survey for anything that will not roll onto a trailer.

  • Oil containment

    Pans, absorbent and a spill plan before a drain plug is touched.

  • Bill of sale

    A document that clears a lien, a lease or a bankruptcy file, not a handwritten note.

  • PCB paperwork

    Testing and manifesting for pre-1979 oil, handled before the unit moves.

On the ground

The 75 kVA class

A 75 kVA nameplate states apparent power capacity, not the connected load or the condition of the windings. A three-phase padmount in this class commonly serves a small retail building or machine shop, with primary elbows and secondary terminals behind locked compartment doors.

Read the complete plate before describing a removed unit as 75 kVA. Record phase count, frequency, cooling designation and serial number. A ventilated dry-type transformer from a Raleigh electrical room needs different handling and inspection than an oil-filled padmount sitting outside.

Local reality

Typical North Carolina applications

At a small retail building in Greensboro, a 75 kVA three-phase padmount may feed a 208Y/120-volt service for lighting, receptacles and smaller mechanical loads.

Confirm the actual secondary voltage from the nameplate; the building's use alone does not establish its electrical configuration.

A machine shop in Hickory may use a 75 kVA dry-type unit to derive 208Y/120 volts from a 480-volt distribution system.

During removal, distinguish that indoor step-down unit from the utility-owned transformer outside, and establish ownership before including either unit in a transfer.

Around the site

Shipping weight and footprint

Shipping weight for a 75 kVA unit is roughly 700 to 1,100 pounds, with construction and enclosure affecting the actual figure. Use the manufacturer's weight marking or documentation for planning.

An oil-filled tank and a ventilated dry-type enclosure should not be assumed identical.

Measure the tank or enclosure, including radiators, hinges and projecting cable compartments, before scheduling removal from a Durham site. Record pad dimensions separately from equipment dimensions. A narrow service gate can prevent passage even when the truck can reach the adjacent parking lot.

Where it sits

Rigging and load-out

A small crane or a boom truck with a spreader bar can handle many 75 kVA removals when capacity, reach and ground conditions are verified. Lift from designated lifting points. Bushings, radiator panels, compartment doors and cable brackets are not substitutes for lifting lugs.

Before load-out from a Wilmington retail pad, have qualified personnel isolate the equipment, verify absence of voltage and disconnect conductors under the applicable safety procedure. Check lifting lugs for corrosion and tank seams for leaks. Plan truck position without obstructing emergency access.

On the ground

Primary and secondary voltages

On a 75 kVA padmount, primary markings may include 12,470Y/7,200 volts or another utility distribution voltage. Secondary connections may be 208Y/120 or 480Y/277 volts.

These are examples, not identification shortcuts; copy the nameplate voltage, connection diagram and tap positions exactly.

For a three-phase 75 kVA unit, rated secondary current is about 208 amperes at 208 volts and 90 amperes at 480 volts. Those figures describe transformer capacity, not permissible building demand or conductor sizing. Include photographs of terminal labels and any altered connections.

Local reality

Inspection and oil test

Inspection of an oil-filled 75 kVA padmount starts with the tank, gasket joints, bushings and cable compartment. Note oil staining below the cover, cracked porcelain, damaged elbows and evidence of bayonet fuse operation. Describe a fault event separately from damage caused during demolition.

For older oil-filled equipment removed in Charlotte, retain available fluid records and PCB documentation. Sampling should follow an appropriate procedure and the receiving requirements.

Dielectric breakdown and moisture results can help describe insulation condition, but an oil test alone does not establish winding integrity.

Around the site

Valuation for this size

Assessment of a 75 kVA transformer depends on its construction, voltage configuration, documented condition and removal requirements. A complete nameplate and clear compartment photographs help distinguish an intact surplus padmount from a failed unit with burned terminals, missing elbows or a leaking tank.

For North Carolina owners, the assessment also needs an accurate site description: approximately 700 to 1,100 pounds, actual dimensions, crane access and ownership paperwork.

Transformer Buyers NC buys this size in used, surplus, failed and obsolete condition, with handling planned around the specific equipment.

Get started

Get an offer in minutes

Five fields is all it takes. Photographs help, but a nameplate and a town are enough to start.

No fee, no obligation. We reply the same business day.

Tell us what you have

We reply the same business day.

or call (614) 715-3047

Questions

Straight answers

Equipment types

How much does a 75 kVA transformer weigh?

A typical shipping weight is roughly 700 to 1,100 pounds. Verify the specific unit's nameplate or manufacturer documentation before selecting rigging. Oil volume, enclosure construction and attached compartments affect weight, so a visual estimate is not enough for a lift plan.

Service area

Can you buy a failed 75 kVA padmount?

Transformer Buyers NC buys failed 75 kVA padmounts in North Carolina. Document the failure, including burned terminals, a leaking tank or fuse operation, and retain available test reports. Ownership, fluid records and safe disconnection still need confirmation before removal.

Payment

What information identifies my 75 kVA transformer?

Provide readable nameplate photographs showing 75 kVA, phase count, primary and secondary voltages, serial number and connection diagram. Include enclosure photographs, dimensions and any oil records. For a machine shop removal, identify whether the unit belongs to the facility or the utility.

Logistics

Primary and secondary voltages: what should a seller know?

On a 75 kVA padmount, primary markings may include 12,470Y/7,200 volts or another utility distribution voltage. Secondary connections may be 208Y/120 or 480Y/277 volts.

One buyer, start to finish

Ready to move that transformer?

Call (614) 715-3047 Get an Offer