Any condition, any size

13.8 kV Class Transformers

Units at this class are priced on the nameplate, the bushings and the oil results, then collected.

What we buy

Ranges we buy on this page

This page covers the identification, inspection and removal of 13.8 kV class transformers at North Carolina generating stations and industrial facilities. It is written for plant engineers, utility asset managers, facility directors and contractors planning equipment retirement.

Transformer Buyers NC buys used, surplus, failed and obsolete units across the state. Nameplate voltage, insulation level, service history and the route from the foundation to the truck guide the assessment.

PhasekVAVoltageFluid
1 or 3-phase25 - 20,000 kVA13.8 kV ClassLiquid or dry
3-phase75 - 10,000 kVAup to 34.5 kVLiquid-filled

Who we buy from

Six kinds of seller

  • Recyclers
  • Electrical contractors
  • Equipment dealers
  • End users
  • Demo contractors
  • Distributors
Finned pad-mounted transformer on a concrete pad in front of a brick plant wall
A finned pad-mount on a pad, brick plant wall behind.
  • Fast offers

    A written offer the same business day, based on your photographs.

  • Dedicated logistics

    Our own crew, trailer and crane, not a brokered haul.

  • No broker fees

    One buyer from first call to cleared pad, with nothing skimmed.

How it works

Six steps from photograph to payment

  1. 01

    Take pictures

    Photograph the nameplate, the inside of the cabinet and the tank from both ends. Four frames on a phone are enough to price most units.

  2. 02

    Send them to us

    Email or text the photographs with the site address and whether the unit is still energised. We reply the same business day with questions or a number.

  3. 03

    Review the offer

    The offer names the unit, the site, the price and the pickup window. It is written, dated and good for thirty days unless the unit changes hands.

  4. 04

    We schedule freight

    A crew, a trailer and a crane if the pad needs one. You get the date and the arrival window, and the site does not have to close for it.

  5. 05

    Testing on arrival

    Winding resistance, insulation resistance and a turns ratio check, plus oil analysis where the unit is liquid-filled. Results travel with the unit.

  6. 06

    Get paid

    Payment is released against the signed bill of sale and the scale ticket, by check or ACH, with the paperwork copy left on site.

What we handle

The parts sellers dread

  • Rigging

    Crane, skates and a route survey for anything that will not roll onto a trailer.

  • Oil containment

    Pans, absorbent and a spill plan before a drain plug is touched.

  • Bill of sale

    A document that clears a lien, a lease or a bankruptcy file, not a handwritten note.

  • PCB paperwork

    Testing and manifesting for pre-1979 oil, handled before the unit moves.

On the ground

What 13.8 kV Class means

The 13.8 kV class is a utility and industrial standard that sits alongside 12.47 kV. Read the actual winding voltages on the nameplate rather than relying on the switchgear label.

A unit serving a 13.8 kV bus may have several secondary windings.

Insulation commonly includes a basic impulse insulation level, or BIL, around 125 kV. Bushings can be interchangeable with the 12.47 kV family, but fit alone does not establish suitability. Confirm the bushing drawing, current rating, creepage distance and terminal arrangement before substitution.

Local reality

North Carolina installations

Generating station auxiliaries are a familiar North Carolina application for 13.8 kV equipment. These transformers support plant service circuits, with winding arrangements determined by the station design.

Retirement records should identify the unit’s former duty, not merely describe it as a station transformer.

Large industrial services also use 13.8 kV, including facilities with their own medium-voltage distribution. At a North Carolina mill or manufacturing campus, the transformer may sit behind an indoor switchgear lineup or inside a fenced yard.

That location shapes isolation and removal planning.

Around the site

Clearances that decide the rigging

A 13.8 kV transformer’s tallest obstruction may be a bushing, conservator or cable box rather than the tank. Measure the complete assembly against the doorway, overhead pipe rack and crane path.

Separate electrical approach limits from the physical clearance needed to lift isolated equipment.

Radiators can extend beyond a North Carolina plant’s original equipment access opening. Record tank dimensions, removable attachments and lifting-lug locations before selecting a spreader bar.

Use the manufacturer’s lifting instructions; radiator headers and bushing flanges are not substitutes for designated lifting points.

Where it sits

Field testing

For a retired 13.8 kV unit, existing test reports often explain more than an exterior photograph. Useful records include insulation resistance, winding resistance and turns-ratio results, with tap positions and test conditions recorded.

Compare results with earlier readings and the manufacturer’s acceptance criteria.

Oil-filled 13.8 kV transformers may also have dissolved gas analysis and moisture reports. A failed unit needs the trip report, relay targets and any evidence of tank pressure or bushing flashover.

Testing belongs with qualified personnel after isolation, absence-of-voltage verification and appropriate grounding.

On the ground

Moving high-voltage equipment

Moving a 13.8 kV transformer starts with verified shipping weight, not an estimate from tank size. The nameplate or outline drawing should distinguish assembled weight from oil and accessory weights.

Lowboy selection depends on loaded height, axle loading and the North Carolina haul route.

Before loading at a generating station, document which 13.8 kV bushings, radiators and cable boxes remain attached. Removed openings need suitable covers, and loose accessories need identification.

Confirm oil containment, transport orientation and securement requirements with the carrier and the manufacturer’s handling instructions.

Local reality

Valuation notes

Assessment of a 13.8 kV transformer starts with its nameplate: kVA, winding voltages, phase count, impedance, cooling designation and tap range. BIL and connection diagrams matter too. A legible photograph prevents confusion between a 13.8 kV primary and a different winding designation.

Condition records distinguish a serviceable 13.8 kV unit from one retired after an internal fault. Include leak locations, missing bushings, damaged radiators and any oil analysis. For older North Carolina equipment, provide PCB documentation where applicable rather than assuming age establishes fluid classification.

Around the site

Next steps

For a North Carolina 13.8 kV transformer review, assemble nameplate photographs, overall views and the latest available test reports. Include the site address, ownership contact and retirement status. Photographs should show all sides of the tank, terminal compartments and the access route.

Transformer Buyers NC buys 13.8 kV units statewide, including failed and obsolete equipment. Before removal planning, identify who controls switching, disconnection and site access. Plant shutdown dates, crane restrictions and documentation of authority to release the transformer help establish a workable pickup sequence.

Get started

Get an offer in minutes

Five fields is all it takes. Photographs help, but a nameplate and a town are enough to start.

No fee, no obligation. We reply the same business day.

Tell us what you have

We reply the same business day.

or call (614) 715-3047

Questions

Straight answers

Equipment types

Are 13.8 kV and 12.47 kV transformers interchangeable?

Not automatically. The two families can share interchangeable bushings, but transformer winding voltages, tap ranges, insulation ratings and connections still govern application. For a 13.8 kV unit, provide the nameplate and connection diagram rather than treating similar external hardware as proof of compatibility.

Service area

Can you buy a failed 13.8 kV transformer?

Yes. Transformer Buyers NC buys failed 13.8 kV transformers across North Carolina. Document the failure, including relay operation, visible bushing damage, oil leakage or tank deformation. State whether the unit remains connected and provide available oil reports and incident records.

Payment

What records help plan a generating station removal?

For a 13.8 kV generating station auxiliary transformer, gather the outline drawing, shipping weight, lifting instructions and isolation plan. Include access restrictions and photographs of overhead obstructions. Identify the station representative responsible for confirming disconnection and authorizing release before rigging begins.

Logistics

Field testing: what should a seller know?

For a retired 13.8 kV unit, existing test reports often explain more than an exterior photograph. Useful records include insulation resistance, winding resistance and turns-ratio results, with tap positions and test conditions recorded.