Transformer Buyers NC Sell a unit(614) 715-3047
Finned pad-mounted transformer on a concrete pad in front of a brick plant wall

Offer before pickup

Pad-Mounted Transformers

This class turns up in plants and substations across North Carolina, and we collect it in any condition.

What we buy

Ranges we buy on this page

Transformer Buyers NC buys used, surplus, failed and obsolete pad-mounted transformers anywhere in North Carolina. This page covers the locked enclosure, oil-filled tank, inspection records and lifting arrangements that determine how a unit can leave its concrete pad.

PhasekVAVoltageFluid
3-phase75 - 2,500 kVA34.5 kVLiquid-filled

Who we buy from

Six kinds of seller

  • Recyclers
  • Electrical contractors
  • Equipment dealers
  • End users
  • Demo contractors
  • Distributors
Yard row of pad-mounted transformers against a chain-link fence with overhead wires
The yard row against the fence, wires overhead.
  • Fast offers

    A written offer the same business day, based on your photographs.

  • Dedicated logistics

    Our own crew, trailer and crane, not a brokered haul.

  • No broker fees

    One buyer from first call to cleared pad, with nothing skimmed.

How it works

Six steps from photograph to payment

  1. 01

    Take pictures

    Photograph the nameplate, the inside of the cabinet and the tank from both ends. Four frames on a phone are enough to price most units.

  2. 02

    Send them to us

    Email or text the photographs with the site address and whether the unit is still energised. We reply the same business day with questions or a number.

  3. 03

    Review the offer

    The offer names the unit, the site, the price and the pickup window. It is written, dated and good for thirty days unless the unit changes hands.

  4. 04

    We schedule freight

    A crew, a trailer and a crane if the pad needs one. You get the date and the arrival window, and the site does not have to close for it.

  5. 05

    Testing on arrival

    Winding resistance, insulation resistance and a turns ratio check, plus oil analysis where the unit is liquid-filled. Results travel with the unit.

  6. 06

    Get paid

    Payment is released against the signed bill of sale and the scale ticket, by check or ACH, with the paperwork copy left on site.

What we handle

The parts sellers dread

  • Rigging

    Crane, skates and a route survey for anything that will not roll onto a trailer.

  • Oil containment

    Pans, absorbent and a spill plan before a drain plug is touched.

  • Bill of sale

    A document that clears a lien, a lease or a bankruptcy file, not a handwritten note.

  • PCB paperwork

    Testing and manifesting for pre-1979 oil, handled before the unit moves.

On the ground

The unit itself

The pad-mounted unit covered here is a dead-front, tamper-resistant three-phase transformer in a locked steel enclosure on a concrete pad. Its cable compartment separates service connections from public access.

Inside that compartment, high-voltage elbows connect shielded underground cable to bushings; the tank behind it contains the core, windings and insulating oil.

Nameplate photographs should show kVA, primary and secondary voltages, serial number, impedance and manufacture date. A 12,470-volt primary with a 480Y/277-volt secondary describes a different service arrangement from a 208Y/120-volt unit.

Include the connection diagram and any labels identifying loop-feed or radial-feed construction, along with photographs of the closed enclosure.

Local reality

Where you find pad-mounted in this state

Across North Carolina, pad-mounted transformers serve shopping centers, apartment complexes, schools and small industrial parks. They appear throughout utility service territories statewide, including Duke Energy, municipal systems and electric cooperatives.

A unit behind a school cafeteria may have restricted truck access even when the nearby parking lot looks open enough for removal.

Ownership needs confirmation before removal from any North Carolina property. The transformer beside an apartment building may belong to the serving utility rather than the building owner.

Utility asset records, service agreements and written release documents establish who can authorize transfer; a demolition permit alone does not establish ownership of the pad-mounted unit.

Around the site

Our inspection list

We inspect tank condition, oil level, high-voltage elbows, bayonet fuses and whether the enclosure still latches. Rust along the tank base, wet gasket seams and distorted doors deserve clear photographs.

A missing latch or damaged locking provision matters because the cable compartment must remain secured until qualified personnel control access for inspection.

With the unit safely isolated, qualified personnel can document cracked elbow housings, damaged bushing interfaces and evidence of tracking in the cable compartment. Bayonet fuse condition and the reason for any fuse replacement help explain a failure.

Photograph lower door edges and hinge mounts, where corrosion can prevent the enclosure from closing properly.

Where it sits

Testing, oil and liability

Existing test reports can separate a serviceable padmount from a unit removed after an internal fault. Useful records include insulation resistance, turns ratio, winding resistance and oil test results.

Record the test date and the connections tested; a report without a matching serial number cannot reliably describe the transformer sitting on the pad.

Oil handling requires the unit's own records, not assumptions based on enclosure color or apparent age. Provide any PCB analysis, oil sampling history and spill documentation.

A leaking tank at a school or apartment complex also requires site-specific containment planning, with responsibility for sampling, cleanup and transport documentation established before lifting begins.

On the ground

Load-out and haul

A padmount is lifted from its concrete pad, not dragged across it. Confirm lifting points, documented weight and crane access before scheduling removal. Cable trenches, landscape walls and overhead conductors can restrict the lift.

If the unit is set in a well, the concrete has to be cut to permit safe extraction.

Disconnection belongs to qualified personnel working under the applicable utility and site procedures, with isolation verified before cable handling. The lift plan should address rated rigging, a spreader bar where needed and protection for bushings and radiators.

Trailer selection depends on dimensions, weight, loading method and access through the actual North Carolina site gate.

Local reality

Valuation factors

Assessment starts with the padmount's nameplate and documented condition: kVA, voltage combination, age, winding material and test history. Loop-feed construction, elbow interfaces and fuse arrangement distinguish otherwise similar enclosures.

A complete, dry tank with readable records presents a different evaluation from a burned unit with missing bushings and an unreadable nameplate.

Removal conditions also affect the assessment of a pad-mounted transformer. A unit beside an accessible industrial driveway differs from one trapped below grade behind an apartment courtyard wall. Identify attached cables, oil leakage, damaged lifting provisions and concrete cutting requirements.

These details establish the handling work rather than leaving it to discovery during load-out.

Around the site

How to start the conversation

Start with photographs of the nameplate, all enclosure sides, the concrete pad and the truck approach. Include the North Carolina location, ownership documentation and whether the unit remains connected to utility service.

Cable-compartment photographs should come only from authorized personnel; opening a locked padmount is not a task for a general site photographer.

For a failed padmount, describe the event and provide available fuse, relay or oil records. For a surplus unit, explain when it was disconnected and how it has been secured since removal from service.

Note school access windows, apartment traffic restrictions or utility coordination requirements so the proposed removal matches the actual site conditions.

Get started

Get an offer in minutes

Five fields is all it takes. Photographs help, but a nameplate and a town are enough to start.

No fee, no obligation. We reply the same business day.

Tell us what you have

We reply the same business day.

or call (614) 715-3047

Questions

Straight answers

Equipment types

Can you buy a failed pad-mounted transformer?

We buy failed pad-mounted transformers in North Carolina. Document the failure, tank leakage, fuse condition and any available testing. Keep the enclosure secured and identify who owns the unit. Internal damage and oil condition need assessment before a removal plan is established.

Service area

Who owns the padmount outside my building?

The serving utility may own the pad-mounted transformer even when it sits on privately owned land. Check service agreements and utility asset records before authorizing removal. A property deed or demolition contract does not, by itself, confirm ownership of the transformer.

Payment

What happens if the transformer sits in a well?

A padmount set in a well requires concrete cutting to permit extraction. Document the well dimensions, cable entrances and surrounding access before planning the lift. The unit must be lifted, not dragged, with qualified personnel coordinating electrical isolation and cable disconnection.

Logistics

Testing, oil and liability: what should a seller know?

Existing test reports can separate a serviceable padmount from a unit removed after an internal fault. Useful records include insulation resistance, turns ratio, winding resistance and oil test results.

One buyer, start to finish

Ready to move that transformer?

Call (614) 715-3047 Get an Offer