Hurricane Preparation

A plain-language guide for anyone in North Carolina holding a transformer and unsure what happens next.

What we buy

Ranges we buy on this page

This guide covers what a coastal North Carolina facility should do with its transformers and associated electrical equipment before hurricane landfall. It is written for plant engineers, hospital facilities directors, utility asset managers, and contractors responsible for exposed pads, electrical rooms, and shutdown decisions.

The priorities are flood exposure, safe isolation, equipment records, and access after the storm. A flooded transformer requires qualified evaluation, not a quick restart.

PhasekVAVoltageFluid
1-phase10 - 333 kVAup to 25 kVLiquid or dry
3-phase50 - 20,000 kVA115 kVLiquid or dry

Who we buy from

Six kinds of seller

  • Recyclers
  • Electrical contractors
  • Equipment dealers
  • End users
  • Demo contractors
  • Distributors
Single pad-mounted transformer on grass with coiled cable at the fence line
A single pad-mount on grass, coiled cable at the fence line.
  • Fast offers

    A written offer the same business day, based on your photographs.

  • Dedicated logistics

    Our own crew, trailer and crane, not a brokered haul.

  • No broker fees

    One buyer from first call to cleared pad, with nothing skimmed.

How it works

Six steps from photograph to payment

  1. 01

    Take pictures

    Photograph the nameplate, the inside of the cabinet and the tank from both ends. Four frames on a phone are enough to price most units.

  2. 02

    Send them to us

    Email or text the photographs with the site address and whether the unit is still energised. We reply the same business day with questions or a number.

  3. 03

    Review the offer

    The offer names the unit, the site, the price and the pickup window. It is written, dated and good for thirty days unless the unit changes hands.

  4. 04

    We schedule freight

    A crew, a trailer and a crane if the pad needs one. You get the date and the arrival window, and the site does not have to close for it.

  5. 05

    Testing on arrival

    Winding resistance, insulation resistance and a turns ratio check, plus oil analysis where the unit is liquid-filled. Results travel with the unit.

  6. 06

    Get paid

    Payment is released against the signed bill of sale and the scale ticket, by check or ACH, with the paperwork copy left on site.

What we handle

The parts sellers dread

  • Rigging

    Crane, skates and a route survey for anything that will not roll onto a trailer.

  • Oil containment

    Pans, absorbent and a spill plan before a drain plug is touched.

  • Bill of sale

    A document that clears a lien, a lease or a bankruptcy file, not a handwritten note.

  • PCB paperwork

    Testing and manifesting for pre-1979 oil, handled before the unit moves.

On the ground

The short version

Before landfall, walk the transformer pad with the facility’s electrical lead. Note nearby drainage inlets, loose fencing, overhanging limbs, and the elevation of cable compartments. Along the coast, storm surge can reach equipment that has never flooded during heavy rain.

Photograph the pad and surrounding grade.

Set shutdown triggers before wind and water restrict access. Identify who can authorize isolation, which loads require continuity, and which switching steps belong to the utility.

Record the transformer’s nameplate, serial number, kVA, primary voltage, secondary voltage, and fluid type while the compartment remains safely accessible.

Local reality

Why a seller should care

A surplus transformer sitting beside a Wilmington warehouse still needs a storm plan, even if it is disconnected. Windborne sheet metal can break a bushing, and saltwater can enter an unsecured cable compartment.

Document its condition before landfall so later damage is not mistaken for an existing defect.

Transformer Buyers NC buys used, surplus, failed, and obsolete transformers throughout North Carolina. For equipment exposed to a hurricane, the useful record includes flood depth, exposure duration, photographs, and any inspection findings.

Keep those records with ownership documentation rather than relying on a verbal account after cleanup.

Around the site

The arithmetic

Compare forecast water elevation with the actual elevation of vulnerable components, using the same vertical datum. A pad height measured above nearby pavement is not directly comparable with a storm surge forecast referenced to another datum.

Include cable entries, control cabinets, and basement switchgear in the comparison.

For standby power, list the loads that must operate through an outage and have the electrical engineer verify generator capacity, motor starting demands, and transfer arrangements. A transformer’s kVA rating alone does not establish backup capacity.

Hospital continuity plans must account for downstream distribution, not just the generator.

Where it sits

Where people go wrong

Do not wrap an operating transformer in plastic or block radiator airflow with improvised flood barriers. Temporary protection must preserve required clearances, cooling, and access.

Place barriers only under an engineered plan that considers water pressure, drainage, anchorage, and the possibility of trapping water around the pad.

Never assume a flooded compartment is safe because the building has lost power. Utility restoration, generators, and other sources can energize conductors unexpectedly. Qualified personnel must establish isolation and verify absence of voltage under the applicable procedure.

Do not open compartments, handle elbows, or attempt switching in standing water.

On the ground

Value impact

Saltwater exposure changes the condition assessment even when a tank looks intact. Conductive residue can remain on bushings and insulating surfaces after water recedes. Corrosion can affect terminals, fuse hardware, and enclosure seams.

Record the waterline before cleaning, and distinguish external wetting from suspected fluid or winding contamination.

An inspection report should identify submerged components, damaged gaskets, fluid leaks, and tests recommended by the manufacturer or evaluating specialist. Do not describe hurricane-exposed equipment as operational merely because it energized once.

Accurate condition records help determine whether it warrants further evaluation or should remain isolated for removal.

Local reality

Your next move

Build a pre-landfall file with nameplate photographs, a one-line diagram, utility contacts, shutdown authority, and the site’s flood exposure notes. Store a copy where staff can reach it during an outage.

Include gate access and alternate approach routes if a coastal road or loading area becomes impassable.

If a transformer is already designated for removal, coordinate the schedule before storm conditions develop. Confirm isolation responsibilities, rigging access, equipment weight, and whether saturated ground could prevent crane or lowboy access.

After landfall, reassess the route and pad before moving equipment; the original lift plan may no longer apply.

Get started

Get an offer in minutes

Five fields is all it takes. Photographs help, but a nameplate and a town are enough to start.

No fee, no obligation. We reply the same business day.

Tell us what you have

We reply the same business day.

or call (614) 715-3047

Questions

Straight answers

Equipment types

Should we shut down transformers before hurricane landfall?

Use a site-specific shutdown plan developed by qualified electrical personnel and coordinated with the utility where necessary. Forecast flooding, access restrictions, and essential loads should inform the decision. Do not wait until water surrounds the pad to arrange switching or isolation.

Service area

Can a flooded transformer return to service immediately?

No. Keep hurricane-flooded equipment isolated until qualified personnel evaluate it under manufacturer guidance and applicable requirements. Saltwater residue, contaminated insulation, damaged terminations, and water entry can remain hidden. Dry exterior paint does not establish that the transformer or its cable compartment is safe.

Payment

What records should accompany a storm-damaged transformer?

Keep nameplate photographs, ownership documentation, pre-storm condition photographs, the observed waterline, and inspection or test reports. Note whether exposure involved rainwater, storm surge, or an unknown source. Include isolation status and access restrictions so an evaluation or removal crew can plan safely.